Transformer Ground Resistance Tester

Insulation Resistance Tester is widely used in maintenance of electrical equipment intransformer substation,power plant,etc.It is suitable for carrying out measurement of insulation resistance(IR),absorption ratio(DAR)and polarization index(PI)of all kinds of high voltage equipment,including switchgear transformer sreactors,capacitors,motors,generators and cables,etc.
1. Microcomputer oontrol,menu operation and LCD screen dot matrix display.
2. Output high voltage of each range can be continuous…

SKU: TGRT-113

Description

Insulation Resistance Tester is widely used in maintenance of electrical equipment intransformer substation,power plant,etc.It is suitable for carrying out measurement of insulation resistance(IR),absorption ratio(DAR)and polarization index(PI)of all kinds of high voltage equipment,including switchgear transformer sreactors,capacitors,motors,generators and cables,etc.

1. Microcomputer oontrol,menu operation and LCD screen dot matrix display.
2. Output high voltage of each range can be continuously adjusted from zero.
3. Able to withstand impact of short circuit and residual voltage of the measured capacitance.
4. Maximum resistance measurement range up to 10TΩ,automatic switching range.
5. Automatic measurement of ambient temperature,air humidity and test time.

6. Storage of 60 groups of measuring results,and the data will not be ost for 20 years.

Rated test voltage GD3126A(5KV) GD3126B(10kV)
50V,100V,250 V,500V,1.0kV,
2.5KV,5.0kV
50V,100V,250 V,500V,1.0kV,
2.5KV,5.0kV,10.0kV
Output voltage error ±5%
Resistance range Upper limit 100GQ-10TΩ 100GΩ-20TΩ
Lower limit 0.1MΩ 0.1MΩ
Accuracy Class 5.0
High voltage display error ±(5% ·Ux+1d)
Temperature measuring error ±0.5ºC
Humidity measuring error ±2%RH
Short circuit current Approx.6mA
Voltage ripple <3%
Insulation resistance >500 MQ(between test wire and case)
Withstand voltage AC10.0kV 50Hz 1min(between test wire and case)
Power supply 14.8V lithium battery
Batter service time after one charging 30 days 10 times DAR &5 times Pl test per day
Working temperature and humidity 0ºC~+40ºC<85%RH
Storage temperature and humidity -20ºC~+50ºC<90%RH
Dimension(mm) 325(L)*250(W)*130(H)
Weight 3.7kg
Resistance measuring error
Voltage steps 50 V 100 V 250 V 500 V 1.0 kV 2.5 kV 5.0 kV 10.0 kV
±(3% ·Rx+1d) 0.2GΩ 0.4GΩ 1GΩ 2GΩ 4GΩ 10GΩ 20GQ 40GQ
±(5% ·Rx+1d) 2GΩ 4GQ 10GΩ 20GQ 40GQ 0.1TQ 0.2TQ 0.4TΩ
±(10% ·Rx+2d) 20GΩ 40GΩ 100GΩ 200GΩ 0.4TQ 1TΩ 2TQ 4TQ
±(25% ·Rx+2d) 100GΩ 200GΩ 500GΩ 1TΩ 2TQ 5TΩ 10TQ 20TΩ

xq_04