The Bay-O-Net fuse holder is designed for use in
pad-mounted or subsurface distribution transformer. It is
used with fuse link to protective the secondary short circuit
faulted of transformer,such as current sensing fuse link, dual
sensing fuse link, dual element fuse link.
The fuse holder is with a flapper valve inside the housing
which closes when it is removed.This results in minimal oil
spillage from the transformer tank which increases safety to
line personnel during fuse changeouts, reduce…
This Insulation Protective Cap is an accessory product to other 15kV 200A products with loadbreak interfaces (bushing inserts, loadbreak junctions, feed thru inserts, etc.).It is designed to physically seal and electrically insulate loadbreak bushing interfaces. When installed on a loadbreak bushing interface, and properly grounded using the attached drain wire, the Loadbreak Insulation Protective Cap provides a submersible, fully shielded insulated cap for energized bushings. The Loadbreak Insu…
The Bushing Insert threads onto a standard 200A bushing well.The combination of the bushing well and bushing insert perform the same function as a one piece integral loadbreak bushing, while providing the flexibility to change the bushing insert in the field, without taking the transformer or other apparatus out of service. The bushing insert and loadbreak elbows are the primary components in all ANSI/IEEE loadbreak connections.
The Bushing Insert incorporates an all copper current path.This pro…
15kV 200A Casing Base For Pad Mounted Transformer
15kV/200A casing base is mainly used for American box transformer, outdoor ring network switchgear and other equipment. It is made of high-quality epoxy resin, and the design of umbrella skirt structure increases climbing.The electric distance greatly improves the electrical safety performance of the equipment.
product structure:
1.Seal ring groove 2.Conductive rod 3.Epoxy casing seat body
Order Information:
order number
Cable cross-sectional…
This plug-in bushing can be used as a fixed section for the entry of medium voltage on switch gears or transformers.
Indoors for vertical or horizontal mounting; outdoors both with and without tension making use of the fitting rubber connector, for vertical or horizontal mounting.
Product name
Rated voltag
Rated current
JYTG-35/630
35KV
630A
The combination of the bushing well and bushing insert perform the same function as a one piece integral loadbreak bushing, while providing the flexibility to change the bushing insert in the field, without taking the transformer or other apparatus out of service. The bushing insert and loadbreak elbows are the primary components in all ANSI/IEEE loadbreak connections. No special tools are required for installation. The bushing insert can be installed by hand or with the assistance of a torque t…
Under Oil MOV Surge Arrester
The under oil MOV arrester is designed in accordance with IEEE Std C62.1, and for either horizontal or vertical mounting inside the distribution transformer tank to eliminate the
difficulties associated with externally mounted arresters.
When placed under oil the MOV arrester benefits from the cooling effect of the circulating oil. In addition, under-oil mounting of the arrester eliminates the possibility of shortened arrester life due to high surface contamination,…
24kV/250A elbow cable connector can be installed horizontally and reduce the bending radius of current.Applicable cable section is between 35 mm
2
to 150mm
2
.
product structure:
Stud bolt
Inner and Outer Semiconducting Layer
Insulating layer
Voltage test point
Crimping terminal
Grounding point
Stress cone
order number
Cable cross-sectional area/mm
2
Conductor diameter/mm
Cable insulation outer diameter/mm
NRZT-15/200-35
35
7.0-7.5
17.0-19.0
NRZT-15/200-50
50
8.0-8.5
18.0-20.0
NRZT-15/200-70
70…
Bus-bar Connector is widely applicable for the combined connection of ring main units (RMU), gas insulated switchgear (GIS) to supply more branches for expansion, which electrically insulate and mechanically seal the connecting busbar and switchgear.
The interface designed to comply with EN 50180 / EN 50181 interface type C and HD 629.1, IEC 60502.4, GB/T 12706.4 etc.
Product name
Rated voltage
Rated current
Bus Cross Connector
20(24)KV
630A
Bus-bar Connector is widely applicable for the combined connection of ring main units (RMU), gas insulated switchgear (GIS) to supply more branches for expansion, which electrically insulate and mechanically seal the connecting busbar and switchgear.
The interface designed to comply with EN 50180 / EN 50181 interface type C and HD 629.1, IEC 60502.4, GB/T 12706.4 etc.
Product name
Rated voltage
Rated current
Bus Terminal Connector
20(24)KV
630A
This plug-in bushing can be used as a fixed section for the entry of medium voltage on switch gears or transformers.
Indoors for vertical or horizontal mounting; outdoors both with and without tension making use of the fitting rubber connector, for vertical or horizontal mounting.
Product name
Rated voltag
Rated current
TGSF6-35/1250-C/F
15KV
630A
QTTG-35/2500-F
15KV
630A
Three-phase pad-mounted transformers is oil-filled,three-phase,commercial pad mounteddistribution transformer specifically designed for outdoor installation on a concrete pad and provideunderground power distribution to commercial,industrial and institutional loads.It is availablein both livefront and dead front construction,for radial feed and loop feed applications,with or without taps,thetransformer uses aluminum or copper winding and is optimized to maximize efficiency and footprint.It hasma…