Description
11.Add or Lithium Select
13.With BMS lithium battery communication function (CAN port)
| MODEL | PV30-1012 VHM | PV30-1014 VHM |
PV30-1512 VHM |
PV30-1524 VHM |
PV30-2012 VHM | PV30-2024 VHM | PV30-3024 VHM |
PV30 -3048 VHM | PV30-4024 VHM |
PV30-4048 VHM | PV30-5048 VHM | PV30-6048 VHM |
| Nominal Battery System Voltage | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 24VDC | 48VDC | 24VDC | 48VDC | 48VDC | 48VDC |
| INVERTER OUTPUT | ||||||||||||
| Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |||||
| Surge Rating | 3000VA | 4500VA | 6000VA | 9000VA | 12000VA | 15000VA | 18000VA | |||||
| Capable Of Starting Electric Motor |
1HP | 1HP | 1HP | 2HP | 3HP | |||||||
| Waveform | Pure sine wave/same as input(bypass mode) | |||||||||||
| Nominal Output Voltage RMS | 220V/230V/240VAC(±10%RMS) | |||||||||||
| Output Frequency | 50Hz/60Hz±0.3Hz | |||||||||||
| Inverter Efficiency (Peak) | >88% | |||||||||||
| Line Mode Efficiency | >95% | |||||||||||
| Power Factor | 1.0 | |||||||||||
| Typical Transfer Time | 10ms(max) | |||||||||||
| Overload | 100%<Load<110%(alarm 5min then stop output and fault code 07) 110%<Load<125%(alarm 60s then stop output and fault code 07) Load>125%(alarm 10s then stop output and fault code 07) |
|||||||||||
| AC INPUT | ||||||||||||
| Voltage | 230VAC | |||||||||||
| Selectable Voltage Range | 155~265VAC(For personal computers) | |||||||||||
| Frequency Range | 50Hz/60Hz(Auto sensing)40~80Hz | |||||||||||
| BATTERY | ||||||||||||
| Minimum start voltage | (10V/10.5V/11V/11.5V/12V)+0.5V for 12VDC mode(*2 for 24VDC,*4 for 48VDC) | |||||||||||
| Low Battery Voltage Alarm | (10V/10.5V/11V/11.5V/12V)+0.5V for 12VDC mode(*2 for 24VDC,*4 for 48VDC) | |||||||||||
| Low Battery Voltage Cut Off | 10V/10.5V/11V/11.5V/12V for 12VDC mode(*2 for 24VDC,*4 for 48VDC) | |||||||||||
| High Battery Voltage Alarm | (12-14.5V)+1V for 12VDC mode(*2 for 24VDC,*4 for 48VDC) | |||||||||||
| High Battery Voltage Recover | (12-14.5V)+0.5V for 12VDC mode(*2 for 24VDC,*4 for 48VDC) | |||||||||||
| Energy Saving Mode | Load ≤50±20W(120V)/100±20W(220V) | |||||||||||
| CHARGER | ||||||||||||
| Output Voltage | Depends on battery type | |||||||||||
| Overcharge Protection S.D. | 15.7VDC for 12VDC mode(*2 for 24VDC mode,*4 for 48VDC mode) | |||||||||||
| Maximum Charge Current | 30A | 20A | 45A | 25A | 60A | 30A | 40A | 20A | 60A | 30A | 35A | 40A |
| PAYPASS &PROTECTION | ||||||||||||
| Input Voltage Waveform | Sine wave(grid or generator) | |||||||||||
| Nominal Input Frequency | 50Hz or 60Hz | |||||||||||
| Overload Protection (SMPS Load) |
Circuit breaker | |||||||||||
| Output Short Circuit Protection | Circuit breaker | |||||||||||
| AC Input Breaker | 1-3K/30A | 4-6K/50A | ||||||||||
| SOLAR CHARGER | ||||||||||||
| Maximum PV Array Power | 1250W | 2500W | 1250W | 2500W | 1250W | 2500W | 2500W | 5000W | 2500W | 5000W | 5000W | 5000w |
| Maximum PV Charge Current | 80A±4A | |||||||||||
| DC Voltage | 12V/24V auto work | 24V/48V auto work | ||||||||||
| MPPT Range @Operating Voltage | 15~95VDC@12V/30~230VDC@24V | 30~230VDC @24V/60~230VDC @48V | ||||||||||
| Maximum PV Array Open Circuit Voltage |
245VDC | |||||||||||
| Standby Power Consumption | <2W | |||||||||||
| MECHANICAL SPECIFICATIONS | ||||||||||||
| Mounting | Wall Mount | |||||||||||
| Machine Dimension(W*H*D)(mm) | 303*493*200 | 305*531*202 | ||||||||||
| Package Dimensions(W*H*D)(mm) | 615*400*319 | 686*400*319 | ||||||||||
| N.W(kg) | / | / | ||||||||||
| G.W(kg) | / | / | ||||||||||
| OTHER | ||||||||||||
| Operating Temperature Range | 0℃to 40℃ | |||||||||||
| Storage Temperature | -15℃to 60℃ | |||||||||||
| Audible Noise | 60dB MAX | |||||||||||
| Display | LED+LCD | |||||||||||
| Standard Warranty | 2 year | |||||||||||
| CERTIFICATION &STANDARDS | ||||||||||||
| CE-EMC+LVD(EN6100-6-3:2007,EN6100-6-1:2017+EN IEC62109-1:2010,EN IEC62109-2:2011) | ||||||||||||